<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-09 18-28-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 53 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.3 kHz 71 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 19039 2,1745
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,2 dBr 4,08 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 18:28, 9.12.2025
RT
"YleX Ilta: Henkka Remes "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6203, 6207, 6205, 6201
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 2,1745 Acquired: 2025/12/09 18.27.44 Total samples: 19039 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,2 dBr MIN: 2,2 dBr AVE: 4,08 dBr % above 12,2 dBr: 0,0 Last value: 4,2 dBr (2025/12/09 18.27.43) 18.14 18.16 18.18 18.20 18.22 18.24 18.26 0 2 4 6 Pm [dBr]